Vita Science Peptides logo
VerifiedBiotechnology

Vita Science Peptides

Vita Science Peptides is based in Vancouver, BC and is listed under Biotechnology.

Vancouver-based supplier of research peptides for laboratory research use only. Analytical documentation supplied with each lot; no medical, dosing or human-use claims.

Overview

Vita Science Peptides is a Vancouver-based supplier of research peptides intended strictly for laboratory research use. We publish analytical documentation for each lot, and the following note explains how to read one of the documents we send with an order. Reading a Mass Spectrometry Report for a Research Peptide A certificate of analysis usually carries two analytical results: an HPLC purity figure and a mass spectrometry confirmation. Most researchers read the first and skim the second. That is a mistake, because the mass spectrum is the only part of the document that confirms the material is actually the peptide that was ordered. Mass spectrometry measures molecular mass. For a peptide, the instrument reports the observed mass-to-charge ratio of the intact molecule, usually as a multiply charged ion. The report should state the expected theoretical mass, calculated from the sequence, and the observed mass. The two should agree closely. A difference of a few tenths of a unit is normal instrument variation. A difference of several units means the material is not the intended sequence, or that a modification, salt form or truncation is present. Pay attention to how the result is expressed. Electrospray ionisation produces a series of peaks at different charge states, and the report should show the deconvoluted mass rather than a single raw peak. If only a raw spectrum is supplied with no interpretation, ask for the deconvoluted value and the theoretical mass side by side. Look at the scale of the spectrum as well. A clean spectrum shows one dominant species. A spectrum with a cluster of large peaks a few units apart often indicates incomplete coupling during synthesis, producing deletion sequences that are close in mass to the target. These are exactly the impurities that an HPLC purity percentage can understate, because closely related sequences often elute near the main peak. Check that the lot number on the mass spec report matches the lot number on the vial and on the HPLC trace. A report that covers a production run rather than a specific lot tells you less than it appears to. Finally, keep the report with the experimental record. If a result is questioned months later, the mass spectrum is the document that establishes identity, and identity is a separate question from purity. A sample can be 99% pure and still be the wrong peptide. All materials discussed here are supplied for laboratory research use only. Website: https://canada-peptides.net

Locations

Headquarters

Vancouver, BC

501-408-7172

View on map

Similar companies

G

Gerostate Alpha

Biotechnology

High-throughput phenotypic screening for drugs that extend lifespan

Novato, CA

Minicircle logo

Minicircle

Biotechnology

DNA minicircles for gene expression

Austin, TX